Design & Investigation of Double Pipe Heat Exchanger With heat transfer enhancement using FDM Delta-Channel Winglet Inserts

  • Tejashri N. More

Abstract

Heat transfer increase methods are cast-off to intensification rate of heat transfer deprived of moving much the general presentation of the system. Heat transfer intensification methods are normally used in areas such as heating and cooling in evaporators, air-conditioning apparatus, thermal power plants, space vehicle, automobile etc. The heat exchanger it is understandable to escalation the turbulence and amalgamating of flow of hot fluid inside the hot fluid pipe by resources of particularly design delta winglets that will be positioned either in the straight-line configuration or staggered configuration. The additional winglets help dual determination of cumulative the superficial area for heat transfer and to recover the blending of particles and thus cumulative heat transfer.


How to cite this article:
More TN, Ghuge NC, Design & Investigation of
Double Pipe Heat Exchanger with heat Transfer
Enhancement using FDM Delta-Channel Winglet
Inserts. J Adv Res Electri Engg Tech 2020; 3(1):
10-13.

References

Amol Ashok Patil, Prof. M.H. Patil, Prof. H.G. Patil, “Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners”, International Journal of Science Technology Management and Research Volume 2 , Issue 1 , January 2017.
[2] N Sreenivasalu Reddy, K Rajagopal, P H Veena, “ Experimental Investigation of Heat Transfer Enhancement of a Double Pipe Heat Exchanger with Helical Fins in the Annulus Side”,
International Journal of Dynamics of Fluids. ISSN 0973-1784 Volume 13, Number 2 (2017), pp. 285-293.
[3] Balamurugan M, Sebakarthick M, “Analysing the Heat Transfer Enhancement of Louvered Strip Inserted Double Pipe Heat Exchanger”, IJRASET, Volume 5 Issue XII December 2017.
[4]Madhav Mishra, U.K.Nayak, “Experimental Investigations Of Double Pipe Heat Exchanger With Triangular Baffles”, (Irjet)Volume: 03 Issue: 08|Aug 2016.
[5] S. Naga Sarada, Jaya Krishna. P, “Experimental Investigations On Heat Transfer Augmentation Using Rotating V-Cut Twisted Tape Inserts In A Circular Tube”, ISSN (Print):2394-6202,(Online):2394-6210,Volume-2,Issue-5,2016.
[6] http://web.mst.edu/~vram/projects/FDM_1.pdf
[7]http://atxhs.org/wiki/File:Replicator_Operation_Class_V20.pdf?page=6
[8]https://www.google.com/search?ei=CCHQW7ObA4j%20vgSGpoiYCQ&ins=false&q=introduction+of+double+pipe+heat+exchanger&oq=&gs_l=mobile-gws-wiz-serp.
Published
2021-10-03
How to Cite
MORE, Tejashri N.. Design & Investigation of Double Pipe Heat Exchanger With heat transfer enhancement using FDM Delta-Channel Winglet Inserts. Journal of Advanced Research in Electrical Engineering and Technology, [S.l.], v. 3, n. 1, p. 10-13, oct. 2021. Available at: <https://thejournalshouse.com/index.php/electrical-engg-technology/article/view/461>. Date accessed: 20 mar. 2023.