Fault Detection and Protection of Transformer by using PLC and SCADA

  • Kakde Pavan B Deparment of Electrical Engineering, Matoshri College of Engineering and Research Center Nashik, India.

Abstract

In this process of power production the transformer is place between
alternator and grid through requisite switch gear arrangement like
Isolator, circuit breaker. If the Transformer is not working properly due
to inadequate cooling method, then the transmission will be affected
resulting in revenue loss for power station. So, it is requisite that the
transformer should be given at most care for its effective operation.
With the help of superintend of transformer it can be done. In the
superintend process, the temperature of oil and winding, over voltage
and over current place a major role and has to be control with in limit.
Since the transformer using generating station is a power transformer
whose capacity around 250 MVA, superintend the temperature, over
current and over voltage of oil and winding is difficult task.
In order to crush the disadvantage of existing control scheme, a
Programmable Logic Controller (PLC) can be used. The software of
PLC can be use easily and mainly be contingent on program written in
its memory. One of the common programming method use in PLC is
Ladder Program (Lad logic). This paper present contraption of automatic
control circuit in PLC to observe the different fault of transformer. This is
online superintend system in combination with PLC and various sensors.
It help to observe the inside as well as outside fault of transformer and
also reduce this fault with the help of various range of constraint which
is said by programmer who operate it on the desk of control panel.

References

[1] Application of programmable logic controllers to substation control and protection, IEEE Transactions on Power Delivery 1994; 9:1.

[2] Rohan Perera & Bogdan Kasztenny, “Application Consideration When Protecting Lines With Tapped and IN-Line Transformer”, previously presented at 2014 texas A&M Conference for Protective Relay Engineers, @ 2014 IEEE – All right reserved 20140210, TP6575-01.

[3] Recommended Practices for Installation, Application, Operation and Maintenance of Dry-Type General Purpose Distribution and Power Transformers, Institute of Electrical and Electronic Engineers (IEEE)C57_94, 1982.

[4] IEEE and IEC Codes to Interpret Incipitent Faults in transformers, Using Gas in Oil Analysis, R. R. Rogers C. E. G.B, Transmission Division, Guilford, Engleand, circa 1995.

[5] IEEE Guide for Diagnostic Field Testing of Electrical Power Apparatus, Part 1: Oil Filled Power Transformers, Regulators, and Reactors, Institute of Electrical and Electronic Engineers (IEEE)62, 1995.5.


[6] NERC System protection and control subcommittee, power plant and transmission system protection coordination, July 2010 [7] Hemant Ahuja, Arikha Singh, Saubhagya Tandon, Shreya shrivastav, Sandeep Patil, ‘‘ Automatic Filling Management System For Industries’’ IJETAE, Vol. 4, Special Issue 1, February – 2014
[8] Nabil Shaukat, “A PLC Based Automatic Liquid Filling Process”, IEEE, publication page No. 226-233, 2002.
[9]. Ahmed ulla Abu Saeed, Md. Al-mamun, A.H.M. Zadidul Karim, ‘‘Industrial Application Of PLCs in Bangladesh’’ IJSER, Vol. 3, Issue 6, June 2012.
[10]. Gray Dunning, “Introduction to programmable Logic Controllers,” Delmar ThomsonLearning1998
Published
2021-10-03
How to Cite
PAVAN B, Kakde. Fault Detection and Protection of Transformer by using PLC and SCADA. Journal of Advanced Research in Signal Processing and Applications, [S.l.], v. 2, n. 1, p. 16-19, oct. 2021. Available at: <http://thejournalshouse.com/index.php/SignalProcessing-Applications/article/view/451>. Date accessed: 19 may 2024.